flow measuring instrument
Basic Info
Model No.: MT-100F
Product Description
Packaging & Shipping
Packaging Detail: | Paper Carton, with 1 set main unit, 5 meter *2 shielded transducer cable(standard), 1pair of sensors(Clamp-on / Insertion type) in it. |
Delivery Detail: | 10 workdays after reciept of payment for Visual water flow indicator controller |
MT100Fseries seperate fixed ultrasonic flowmeters are applicable to measure liquid flow in industry application. Mainframe include wall-mounted standard type, wall mounted ex-proof type and panel type. Sensors include clamp-on type, insertion type, inline type. Technology Features of Ultrasonic Flow Meter price
1. Operating Power: | AC 85—264V or isolation DC 24V |
2. Current: | 50mA(under the condition of connection without keyboard display and alarm of beeper) |
3. Signal Output : | *One channel standard isolation RS485 output *One channel isolation 4-20mA or 0-20mA active output. *One channel OCT output [programmed between the pulse width(6-1000ms), default before leaving factory (200ms)] *One channel isolation relay output, with positive, negative, net totaliser pulses and different alarm signals. |
4. Signal Input: | *Two channel three wire system PT100 platinum resistor input loop, to make heat meter has the function of displaying heat quantity. *Three channel 4-20mA input optional,accuracy:0.1%, has the ability to input the signals of pressure, liquid level, temperature and so on. |
5. Display: | 2×20 backlit LCD(Chinese and English optional) |
6. Operating: | 4×4 tactile keypad or magnetic 4 keypads operating(F4 mainframe) |
7. Other Functions: | *Automatic memory the positive, negative, net totaliser or flow rate and thermal energy of the last 512 days, 128months, 10years *Automatic memory the time of power turning on and off and flow rate of the last 30 times, realize to compensate by hand or automatically read the datas through Modbus communication protocol. |
8. Protection Level: | *Mainframe: IP65 *Transducer: IP68 |
9. Ex-proof: | EXd Ⅱ BT4(TDS-100F2 type) |
1. Clamp-on transducer(standard S1 style, standard M1 style, high temperature S1H, high temperature M1H) 2. Insertion transducer(standard insertion B,cement insertion B) 3. In line type transducer(hygienic style, π style, standard style) 4. PT100 3 wire system platinum resistor(one pair, used for heat meter) Transducer of flow measuring instrument
Clamp-on Transducer A pair of clamp-on transducer to measure the flow from outside of a pipe, there is no pressure drop, no moving parts, no leaks and no contamination. The installation is very simple and no special skills or tools are required. Insertion wetted transducer A pair of insertion-type transducers are inserted into the pipe wall to interrogate the flow in the pipe. Since the transducers do not extrude into the flow, they do not generate any disturbance or cause any pressure drop. There is no moving parts to wear out. If the pipe material is carbon steel or stainless steel can be installed directly welding,but if the pipe material is cast iron, FRP,PVC or cement please contact with the manufacturer to order the dedicated pipe hoop. To prevent leak water please give the exact outside diameter or perimeter to the manufacturer. In line type Transducer Transducer is a flow-cell (or spool-piece), where a pair of ultrasonic sensors have already been built in. The flow cell transducer is accurately calibrated in the factory. When it is put in line with the testing pipe, the accuracy normally does not change. with high accuracy, good stability, easy to use, etc.
Technical parameters | Articulate type transducer | PI-type transducer | Standard pipe transducer | |
Main unit | Integrative type ,wall-mount, transmission ,module | Integrative type ,wall-mount, transmission, module, water meter | ||
Pipe size | DN25-DN80mm | DN15-DN40 | DN50-DN1000 | |
Material | stainless steel | carbon steel (stainless steel is optional) | ||
Frequency | 1MHZ | |||
Connection | articulate type | flange type | ||
Application of temperature | -40°C-160°C | |||
Calibration | Calibrate with the main unit | |||
Protection class | IP68(can work in water, and water depth≤3 meter) | |||
Dimension | refer to the following table | |||
Nominal pressure | refer to the following table | |||
Liquid types | Water,sea water.waste water,chemical liquids,oil,crude oil,alcohol,beer,etc. | |||
Suspension concentration | ≤2000ppm,may contain very small amount of air bubbles. | |||
Dedicated shielded transducer cable | Shielded transducer cable,can be extended to 500 meter×2, contact the manufacturer for longer cable requirement. |
Our Services 1.We have aquired ISO, CE,TUV and BQC and other International Certificate;
2.Our flowmeter obtain the APPEARANCE DESIGN PATENT, UTILITITY MODEL PATENT ETC which can distinguish our flowmeter from other suppliers;
3.We have our own QUALITY CONTROL SYSTEM, domestic unique largest-diameter calibration equipment checking ability from DN10 to DN2000; 0-10cubic and 0-65cubic Volumetric Standard; 4.Name: Ultrasonic Flow Meter
Company Information Workshops and warehouses We have our own factories and workshop to ensure the quanlity and delivery, so as the reputation related to our long run development. Q&C team will make our product enough warranty and credit for our domestic and aboard users. Clients visit For years, we accept many users from more than 30 countries, the fame of Metery Tech.becomes more and more popular and attracts more and more attenttion. 1. Customers visit our factory 2. Old customer visit International certificates of flow measuring instrument
Contact us if you need more details on Flow Measuring Instrument. We are ready to answer your questions on packaging, logistics, certification or any other aspects about Flow Measuring Instrument、Flow Measuring Instrument. If these products fail to match your need, please contact us and we would like to provide relevant information.
Product Categories : Ultrasonic Flow Meter > Fixed Ultrasonic Flowmeter